ULS Ultrasonic Level Sensor || ATEK
Ultrasonic working principle
0.5 – 9 meters measuring distance
4-20mA, 0-10V, 0-20 mA analog output options available
CANopen, RS485, RS232 serial communication options
IP65 or IP67 protection class
Robust housing
Non-contact, level and volume measurement of liquid and solid materials in open and closed tanks, measuring range can be calibrated from the menu
Measuring Range | Output | Taper Angle | Accuracy | Protection | Datasheet |
---|---|---|---|---|---|
0.5 – 9 meters | 4-20 mA, 0-20 mA, 0-10V, CANopen, RS-232, RS-485, 2xPNP Open Collector | 30° | %0,2 FS | IP65 or IP67 | ![]() |
- Ultrasonic working principle
- 0.5 – 9 meters measuring range
- Non-contact and high precision measurement
- ±%0.2 FS accuracy
- Single line 5 digit display and 4 sealed keypads for configuration
- Display of measured value in level, distance (cm, m, inch or feet) or volume (liters, m3, imp, gallons)
- RS-232, RS-485 and CANopen serial connection options
- 4-20 mA, 0-20 mA or 0-10V analog output options
- 2 x PNP Open Collector
- IP65 (with transparent cover) or IP67 (with aluminum cover) protection class
- Economical and maintenance-free design
- Easy installation
Marka |
Atek |
---|---|
Measuring Principle |
Non-contact with ultrasonic principle |
Operating range |
0.5 – 9 meters |
Blind area |
50 cm max. |
Measurement Frequency |
40 kHz |
Accuracy |
± % 0,2 FS |
Supply Voltage |
16…30 VDC |
Power consumption |
2,4 Watt max. |
Current consumption |
100 mA max. @24 VDC / 150 mA max. @16 VDC |
Sampling rate |
4 Hz |
Ultrasonic taper angle |
35° |
Minimum resolution |
1 mm |
Relay outputs (Optional) |
2 x PNP Open Collector |
Serial connection (Optional) |
RS-232, RS-485, CANopen |
Analog outputs (Optional) |
0-10 V, 4-20 mA, 0-20 mA |
Analog output load |
500 Ω |
Analog output resolution |
16 Bit |
Tare input (Optional) |
+Vcc (16…30 VDC) |
Reverse connection protection |
Yes |
Overload protection |
Yes (600 mA) |
Temperature compensation |
Yes |
Watchdog |
Yes |
Electrical connection |
M12 / 8 pin male and M12 / 5 pin female sockets (standard) |
Cable length |
Optional |
Operating temperature |
-40 °C … 75 °C |
Storage temperature |
-40 °C … 85 °C |
Protection class |
With transparent cover: IP65 |
Housing material |
Delrin® POM-C EN 10204 |
Benzer Ürünler
BTE 22 Hydrostatic Level Sensor || ATEK || Made in Türkiye
Special design for textile sector Piezoresistive working principle 316L stainless steel housing Different models between 100 mBar and 600 mBar Analog 4-20mA / 0-10V and so on different outputs ±0.3% F.S accuracy IP65 protection class Compact construction
Special design for textile sector; stainless steel body; air isolated mounting; high sensitivity; EMC and reverse polarization protected; small and compact design
Measuring Range | Output | Protection | Accuracy | Body Diameter | Datasheet |
---|---|---|---|---|---|
Different models from 0...100mbar to 0...600mbar | 4-20 mA, 0-10 VDC, 0-20 mA, 1-6 VDC, 0-5 VDC, Ratiometric etc. | IP65 | ±%0,3 F.S | 23mm | ![]() |
ARD 110 Radar Level Transmitter || Atek
Non-contact liquid level measurement High frequency 80GHz, more focus Accuracy ±2 mm(liquid) Measuring range up to 30m Easy Setup via Bluetooth Small emitting angle ±3.5° 4-20mA + RS485 output G1,5 connection IP67 protection
Ideal for non-contact liquid level measurement in simple applications. It is especially suitable for open channel applications. It can also be used in some liquid tanks and containers. With Bluetooth feature, it allows level reading and adjustment without approaching the tank or hazardous area.Measuring Range | Output | Protection | Accuracy | Datasheet |
---|---|---|---|---|
Up to 30 meters (liquid) | 4-20 mA + RS485 | IP67 | ±2 mm | ![]() |
ARD 210 Radar Level Transmitter || Atek
Non-contact liquid level measurement High frequency 80GHz, more focus Accuracy ±2 mm(liquid) Measuring range up to 30m Easy Setup via Bluetooth Small emitting angle ±3.5° 4-20 mA+HART+RS485 output G1,5 connection IP67 protection
Ideal for non-contact liquid level measurement in simple applications. It is especially suitable for open channel applications. It can also be used in some liquid tanks and containers. With Bluetooth feature, it allows level reading and adjustment without approaching the tank or hazardous area.Measuring Range | Output | Protection | Accuracy | Datasheet |
---|---|---|---|---|
Up to 30 meters (liquid) | 4-20 mA+HART+RS485 | IP67 | ±2 mm | ![]() |
TLS Series Level Switch With Motor || ATEK ||
Maximum 0.8 bar working pressure 3 different sensitivity settings Relay output 220VAC or 24VDC powered version IP65 protection class Robust housing
The TLS 110 and TLS 210 series motor level sensors are commonly used to determine the lower and upper positions of the level in areas such as Silo, Warehouse, etc., or intermediate values if desired
Working Pressure | Connection Type | Output | Protection | Datasheet |
---|---|---|---|---|
Maximum 0.8 Bar | G1½" and G2½" | Relay(microswitch) | IP65 | ![]() |
ULT30 Ultrasonic Level Sensor || ATEK || Made in Türkiye
Non-contact measurement with ultrasonic principle Different measuring options up to 6 meters Acid-proof option 4-20mA, 0-10V, 0-20 mA analog output options CANopen, RS485, RS232 serial communication options 2 x PNP open collector outputs IP67 protection class
Non-contact, level and volume measurement of liquid and solid materials in open and closed tanks; small structure; 316L, delrin or teflon housing options; acid-proof option
Measuring Range | Output | Taper Angle | Accuracy | Protection | Datasheet |
---|---|---|---|---|---|
Measuring options up to 6 meters | 4-20 mA, 0-20 mA, 0-10V, CANopen, RS-232, RS-485, 2xPNP Open Collector | 10°, 12°, 30° | %0,2 FS | IP67 | ![]() |
CLS 211 Capacitive Level Sensor || ATEK || Made in Türkiye
Suitable for mineral oils Alarm delay time between 0-40 seconds can be selected at the ordering stage 40 Bar pressure resistance Sink (NPN) or source (PNP) output type High accuracy and stability IP67 protection class
Suitable for level measurement in mineral oils, sink (NPN) or source (PNP) output, selectable alarm delay time between 0-40 seconds