LT Series || ATEK || Made in Türkiye
Potentiometric measurement
Short distance measurement
Measurement lengths between 10 mm and 300 mm
Potentiometric, 4-20 mA or 0-10V analog output options
5 m/s operating speed
IP 40 protection class
Potentiometric measurement, short distance measurement; Small body structure, High sensitivity, Long life; Absolute operation thanks to analog outputs, that is, not losing position information in case of power outages
Measuring Range | Output | Protection | Electrical Connection | Linearity | Datasheet |
---|---|---|---|---|---|
50-300mm | 4-20 mA, 0-10V or Potentiometric/span> | IP 40 | DIN 43650-Cor cable | ±%0,1 … ±%1 |
- Short distance measuring scale
- Potentiometric measurement
- Potentiometric, 4-20 mA or 0-10V analog output options
- Optionally cable or DIN 43650-C socket connection
- Measurement lengths between 10 mm and 300 mm
- Long life up to 100 million movements
- High accuracy
- High operating speed up to 5 m/s
- Compact design
Marka |
Atek |
---|---|
Özellikler |
– |
Technical Features
Technicial Specifications |
||||||||||
Model |
LT 010
|
LT 025
|
LT 050
|
LT 075
|
LT 100
|
LT 125
|
LT 150
|
LT 200
|
LT 250
|
LT 300
|
Electrical Stroke (mm) |
10 |
25 |
50 |
75 |
100 |
125 |
150 |
200 |
250 |
300 |
Mechanical Stroke (mm) |
11 |
26 |
51 |
76 |
101 |
126 |
151 |
201 |
251 |
301 |
Independent Linearity |
±%1 |
±%0,5 |
±%0,4 |
±%0,25 |
±%0,2 |
±%0,2 |
±%0,2 |
±%0,1 |
±%0,1 |
±%0,1 |
Repeatability |
0.01 mm |
|||||||||
Maximum Working Speed |
5 m/s |
|||||||||
Resistance Element
|
Kondüktif Plastik |
|||||||||
Resistance |
5K, 10K (other optional) |
|||||||||
Output Signal
|
4-20 mA (optional 0…20 mA), 0-10V or Potentiometric |
|||||||||
Supply |
‘On ‘A’ and ‘V’ models: 12…30 VDC |
|||||||||
In the model with potentiometric output: 42V max. |
||||||||||
Electrical Connection
|
DIN 43650-C soket veya 3 x 0,14mm2 ekranlı kablo
|
|||||||||
Operating temperature |
-30°C…+100°C |
|||||||||
IP Protection Class |
IP40 |
|||||||||
Life |
100 million movement |
|||||||||
Shaft Material |
Stainless steel |
|||||||||
Body Material
|
Aluminum |
Benzer Ürünler
MLC 330 Linear Scale || ATEK || Made in Türkiye
Magnetic measurement Incremental encoder output Contactless / non-friction system Slim profile structure Measuring up to 20 meters Resolution options starting from 5µm IP67 protection class
High accuracy measurement with contactless magnetic system; Slim, retention profile closed system; Sealed protection against harsh environments with dust, humid and oil
Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 20 meters | Push-Pull, TTL RS422 Line Driver | IP 67 | B5 | 5µm, 10µm, 25µm, 50µm, 62.5µm, 100µm, optional other resolutions |
MLC 420 Series Press Brake Linear Encoder || ATEK || Made in Türkiye
Magnetic measurement Incremental utput Stroke up to 2000 mm Resolution options up to 5 µm IP65 protection class Compatible with Delem, Cybelec, ESA and STEP devices Datasheet
High accuracy measurement with contactless magnetic system; special design for press brake machines; movable reference point; high tolerance to shock and vibrations; sealed protection against harsh environments with dust, humid and oilMeasuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 2000 mm |
Push-Pull, TTL RS422 Line Driver |
IP 65 | B2 | 5µm, 10µm, 25µm, 50µm, others on request |
MLS 120 / 121 Series Magnetic Reader Sensor || ATEK || Made in Türkiye
Magnetic measurement Small size Easy mounting Measure up to 100 meters Resolution from 1 μm to 100 μm Model with cable or socket Spiral or PUR cable option IP67 protection class
Reader sensor for contactless measurement on magnetic tape; internal tape slider against dust; extra durability against environmental factors such as moisture, oil, dust; model with cable or socketMeasuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 100 meters |
Push-Pull, TTL RS422 Line Driver |
IP 67 | B2, B5 |
1µm, 5 µm, 10µm, 25µm, 62.5µm, 80µm, 100µm, others on request |
B Series Magnetic Tape || ATEK || Made in Türkiye
Magnetic tape for MLS 110/120/130/210 series Tape length up to 10 meters Stainless steel protection Robust and flexible construction 3-layer structure
Magnetic reader sensors robust and flexible magnetic tape designed for MLS 110/120/130/210 series; 5mm or 2mm pole distance options
Measuring Range | Material | Accuracy | Datasheet |
---|---|---|---|
Up to 100 meters | CrNi 17 7 Stainless steel sheet | 18 µm/m or 20 µm/m |
ALS 6 Thick and Long Body Optical Linear Scale || ATEK || Made in Türkiye
Stroke options from 50 mm to 3200 mm Incremental optical system Thick and long-distance body type Reference point at 50 mm intervals High resolution up to 1 μm IP54 protection class 60 m/min operating speed
Precise measurement on glass surface with optical principle; thick, long-distance body with single seal; 5 ball bearing system orientation; compact design, high accuracyMeasuring Range | Output Type | Protection | Resolution | Datasheet |
---|---|---|---|---|
Different measuring lengths from 50 mm to 3200 mm |
5 VDC TTL Quadrature
or 1Vpp Sinus |
IP 54 | 1µm, 5µm |
AWP 210 Draw Wire Sensor || ATEK || Made in Türkiye
Different stroke (measuring) lengths between 1000 mm and 5000 mm ±0.5% FS linearity Potentiometric, 0-10 VDC or 4-20 mA analog output Easy mounting IP53 protection class
Potentiometric measurement; robust stainless steel wire; anodised aluminum body; resistant to shocks and vibrationsStroke (measuring) Lengths | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 1000 mm and 5000 mm | Potentiometric, 4-20 mA Current, 0-10 VDC Voltage | IP 53 | ±0,5% FS |