ALS 5 Thick Body Optical Linear Scale || ATEK || Made in Türkiye
Stroke options from 100 mm to 1500 mm
Incremental optical system
Thick body type
Reference point at 50 mm intervals
High resolution up to 1 μm
IP54 protection class
60 m/min operating speed
Optical precision measurement on glass surface; thick body with single gasket protection; 5 ball bearing system orientation; compact design, high accuracy
Measuring Range | Output Type | Protection | Resolution | Datasheet |
---|---|---|---|---|
Different measuring lengths from 100 mm to 1500 mm |
TTL RS-422
or Sinus
|
IP 54 | 1µm, 5µm | ![]() |
- Very precise measurement on glass surface with optical principle
- Thick body type with one gasket
- High resolution options starting from 1 μm
- Robust orientation with 5 ball bearing system
- Easy installation
- Stroke options from 100 mm to 1000 mm
- Reference point at 50 mm intervals
- 60 m/min operating speed capability
*We highly recommend using our Process Control Devices to precisely display measured values on your Optical Linear Scale for motion conrolling.
Marka |
Atek |
---|---|
Measuring Type |
Optical |
Measuring Lengths |
Different measuring lengths from 100 mm to 1500 mm |
Resolution |
1µm, 5µm |
Signal Period |
20 µm |
Accuracy |
± 10 µm |
Repeatability |
± 1 pulse |
Max Operating Speed |
60m/min |
Supply Voltage |
5 VDC |
Output Type |
TTL RS-422 or Sinus |
Reference Point |
Every 50 mm |
Body Material |
Aluminium |
Operating Temperature |
0°C … +50°C |
Storage Temperature |
-20°C…+70°C |
Protection Class |
IP54 |
Cable Length |
50 – 500 mm (3 meters armored cable) |
Benzer Ürünler
MLC 410 Series Press Brake Linear Encoder || ATEK || Made in Türkiye
Magnetic measurement Measuring up to 4000 mm Resolution options starting from 5µm Self-embedded bearing system IP67 protection class Compatible with Delem, Cybelec and ESA Datasheet
High accuracy measurement with contactless magnetic system; special design for press brake machines; self-aligning system; extra resistant to harsh conditions such as high temperature, speed or vibration
Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 4000 mm | Push-Pull, TTL RS422 Line Driver | IP 67 | B5 | 5µm, 10µm, 25µm, 50µm, 62.5µm, 100µm, optional other resolutions | ![]() |
MLS 130 Series Magnetic Reader Sensor || ATEK || Made in Türkiye
Magnetic measurement Small size Easy mounting Measure up to 100 meters Resolution from 1 μm to 100 μm Spiral or PUR cable option IP67 protection class
Reader sensor capable of contactless measurement on magnetic tape; the perfect solution for tight spaces with very small size; it is completely insensitive to factors such as moisture, oil, dust, etc.; models with cable or spiralMeasuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 100 meters |
Push-Pull, TTL RS422 Line Driver |
IP 67 | B2, B5 |
1 µm, 5 µm, 10 µm, 25 µm, 62.5 µm, 80µm, 100µm, others on request |
![]() |
MLS 210 Series Magnetic Reader Sensor || ATEK || Made in Türkiye
Magnetic measurement Incremental output Resolution from 5 μm to 100 μm Easy mounting Options with or without chip scraper IP67 protection class
The principle of magnetic non-contact precision measurement; durable aluminum armored, high temperature, extra resistant against harsh conditions such as vibration or speed; options with cable or spiral; slide or slideless options
Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
---|---|---|---|---|---|
Up to 100 meters | Push-Pull, TTL RS422 Line Driver | IP 67 | B5 | 5µm, 10µm, 25µm, 62.5µm, 80µm, 100µm, others on request | ![]() |
ALS 4 Thin Body Optical Linear Scale || ATEK || Made in Türkiye
Stroke options from 100 mm to 1000 mm Incremental optical system Slim body type Reference point at 50 mm intervals High resolution options up to 1 μm IP54 protection class 60 m/min operating speed
Optical precision measurement on glass surface; thin body with single or double gasket protection; 5 ball bearing system orientation; compact design, high accuracyMeasuring Range | Output Type | Protection | Resolution | Datasheet |
---|---|---|---|---|
Different measuring lengths from 100 mm to 1000 mm |
TTL RS-422
or Sinus |
IP 54 | 1µm, 5µm | ![]() |
AWP 110 Draw Wire Sensor || ATEK || Made in Türkiye
Different stroke (measuring) lengths between 100 mm and 1200 mm ±0.5% FS linearity Potentiometric, 0-10 VDC or 4-20 mA analog output Small structure IP53 protection class
Potentiometric measurement; robust stainless steel wire; anodised aluminum and small body; resistant to shocks and vibrationsStroke (measuring) Lengths | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 100 mm and 1200 mm | Potentiometric, 4-20 mA Current, 0-10 VDC Voltage | IP 53 | ±0,5% FS | ![]() |
AWP 404 Draw Wire Sensor || ATEK || Made in Türkiye
Different measuring lengths between 1000 mm and 4000 mm ±0.5% FS linearity Potentiometric, 0-10 VDC, 4-20 mA, CANopen or SSI output options IP54 (Optional IP67) protection class
Potentiometric measurement; robust stainless steel wire; suitable for long distance measurements; anodised aluminum body suitable for outdoor use; resistant to shocks and vibrationsStroke (measuring) Length | Output | Protection | Linearity | Datasheet |
---|---|---|---|---|
Different measuring lengths between 1000 mm and 4000 mm | Potentiometric, 4-20 mA, 0-10 VDC, CANopen, SSI | IP54 (Optional IP67) | ±0,5% FS | ![]() |