Different measuring lengths between 1000 mm and 4000 mm
±0.5% FS linearity
Potentiometric, 0-10 VDC, 4-20 mA, CANopen or SSI output options
IP54 (Optional IP67) protection class
Potentiometric measurement; robust stainless steel wire; suitable for long distance measurements; anodised aluminum body suitable for outdoor use; resistant to shocks and vibrations
| Stroke (measuring) Length | Output | Protection | Linearity | Datasheet |
|---|---|---|---|---|
| Different measuring lengths between 1000 mm and 4000 mm | Potentiometric, 4-20 mA, 0-10 VDC, CANopen, SSI | IP54 (Optional IP67) | ±0,5% FS |
- Different measuring lengths between 1000 mm and 4000 mm
- ±0.5% FS linearity
- Potentiometric, 0-10 VDC, 4-20 mA, CANopen or SSI output options
- IP54 (Optional IP67) protection class
- Compact design
- Easy installation
- Shock/Vibration resistant
- Aluminum anodized body
| Marka |
Atek |
|---|---|
| Stroke (measuring) length |
Different measuring lengths between 1000 mm and 4000 mm |
| Linearity |
±%0.5 FS |
| Supply Voltage |
Current and Voltage output models: 12…30 VDC |
| Signal Output Type |
Potentiometric |
| Measuring Type |
Potentiometric |
| Resistance |
5 KΩ (standard), 10 KΩ |
| Maximum Speed |
0.5 m/s |
| Required Force |
5 N |
| Operating Temperature |
-25°C … +85°C |
| Materials |
Housing: Aluminum/steel /plastic |
| IP Protection Class |
IP54 (Opsiyonel P67) |
- Elevators
- Press machines
- Crane systems
- Wood processing machines
- Marble processing machines
- Storage positioning
- Dam protections
- Sluice gate control
- Air compressors
- Glass processing machines
- Lifting platforms
- Applications in medical technologies (operating table etc.)
- Forklifts
- Screw machines
- Paper machines
- Sewing machines
- Hydraulic machines
- Sheet metal machines
- Printing machines
- Horizontal control equipments
- Construction machines
- Industrial robots
- Injection machines
- X-Y axis displacement
- Liquid level measurements and position control
Benzer Ürünler
MLS 120 / 121 Series Magnetic Reader Sensor || ATEK || Made in Türkiye
Magnetic measurement Small size Easy mounting Measure up to 100 meters Resolution from 1 μm to 100 μm Model with cable or socket Spiral or PUR cable option IP67 protection class
Reader sensor for contactless measurement on magnetic tape; internal tape slider against dust; extra durability against environmental factors such as moisture, oil, dust; model with cable or socket| Measuring Range | Output | Protection | Magnetic Tape | Resolution | Datasheet |
|---|---|---|---|---|---|
| Up to 100 meters |
Push-Pull, TTL RS422 Line Driver |
IP 67 | B2, B5 |
1µm, 5 µm, 10µm, 25µm, 62.5µm, 80µm, 100µm, others on request |
ALS 4 Thin Body Optical Linear Scale || ATEK || Made in Türkiye
Stroke options from 100 mm to 1000 mm Incremental optical system Slim body type Reference point at 50 mm intervals High resolution options up to 1 μm IP54 protection class 60 m/min operating speed
Optical precision measurement on glass surface; thin body with single or double gasket protection; 5 ball bearing system orientation; compact design, high accuracy| Measuring Range | Output Type | Protection | Resolution | Datasheet |
|---|---|---|---|---|
| Different measuring lengths from 100 mm to 1000 mm |
TTL RS-422
or Sinus |
IP 54 | 1µm, 5µm |
ALS 5 Thick Body Optical Linear Scale || ATEK || Made in Türkiye
Stroke options from 100 mm to 1500 mm Incremental optical system Thick body type Reference point at 50 mm intervals High resolution up to 1 μm IP54 protection class 60 m/min operating speed
Optical precision measurement on glass surface; thick body with single gasket protection; 5 ball bearing system orientation; compact design, high accuracy| Measuring Range | Output Type | Protection | Resolution | Datasheet |
|---|---|---|---|---|
| Different measuring lengths from 100 mm to 1500 mm |
TTL RS-422
or Sinus |
IP 54 | 1µm, 5µm |
ALS 6 Thick and Long Body Optical Linear Scale || ATEK || Made in Türkiye
Stroke options from 100 mm to 3200 mm Incremental optical system Thick and long-distance body type Reference point at 50 mm intervals High resolution up to 1 μm IP54 protection class 60 m/min operating speed
Precise measurement on glass surface with optical principle; thick, long-distance body with single seal; 5 ball bearing system orientation; compact design, high accuracy| Measuring Range | Output Type | Protection | Resolution | Datasheet |
|---|---|---|---|---|
| Different measuring lengths from 100 mm to 3200 mm |
TTL RS-422
or Sinus |
IP 54 | 1µm, 5µm |
AWP 508 Draw Wire Sensor || ATEK || Made in Türkiye
Different measuring lengths between 4000 mm and 8000 mm ±0.5% FS linearity Potentiometric, 0-10 VDC, 4-20 mA or CANopen output options IP54 (Optional IP67) protection class
Potentiometric measurement; robust stainless steel wire; suitable for long distance measurements; anodised aluminum body suitable for outdoor use; resistant to shocks and vibrationsAWP 512 Draw Wire Sensor || ATEK || Made in Türkiye
Different stroke (measuring) lengths between 5000 mm and 12000 mm ±1% FS linearity Potentiometric, 0-10 VDC, 4-20 mA or CANopen output options IP54 (Optional IP67) protection class Datasheet
Potentiometric measurement; robust stainless steel wire; suitable for long distance measurements; anodised aluminum body suitable for outdoor use; resistant to shocks and vibrations
Linear Measurement
Rotary Measurement
Pressure Measurement
Inclination/ Tilt Measurement
Laser Distance Sensors
Level Measurement
Temperature Measurement
Liquid Flow Measurement
Proximity Sensors
Joysticks
Dro, Display and Counters
Elevator Light Curtains
Speed and Motion Measurement
Counting Sensors
Mechanical Plunger Switches
Seismic / Earthquake Sensors
Faucet Sensors
Seam Detector Sensors
Encoder Signal Conditioner and Optical Isolator
Couplings
Cable and Connectors