Showing 1–12 of 15 results

BCT 22 Pressure Transmitter || ATEK || Made in Türkiye

Piezoresistive working principle
Stainless steel housing (1.4305)
Optional 316L or titanium housing
Different models between 100 mBar and 600 Bar
Analog 4-20mA / 0-10V and CANopen output options
±0.5% F.S or ± 0.3% F.S accuracy
IP65 or IP67 protection class
Compact construction

Stainless steel body; high sensitivity; EMC and reverse polarization protected; small and compact design

Measuring Range Output Protection Accuracy Body Diameter Datasheet
Different models from 0…100mbar to 0…600bar  Different vacuum models from 0…-100mbar to 0…-1bar 4-20 mA, 0-10 VDC, 0-20 mA, 1-6 VDC, 0-5 VDC, Ratiometric or CANopen IP65 or IP67 ±%0,5 F.S (ceramic), ±%0,3 F.S (silicon) 22mm

BTT 22 Thin-Film Pressure Transmitter || ATEK || Made in Türkiye

Thin-film steel diaphragm structure
23 mm diameter stainless steel housing
Different options up to 1000 Bar
Analog 4-20mA / 0-10V etc. outputs
±%0,5 F.S accuracy
Compact design

Fully welded Thin-film steel diaphragm structure that does not require O-rings; High sensitivity; EMC and reverse polarition protection; Small and compact design

 Pressure Range Output Protection Accuracy Body Diameter Datasheet
Different options up to 1000 Bar 4-20 mA, 0-10 VDC, 0-20 mA, 1-6 VDC, 0-5 VDC, Ratiometric IP65 or IP67 ±%0,5 F.S 23mm

BTT 26 Thin-Film Pressure Transmitter || ATEK || Made in Türkiye

Thin-film steel diaphragm structure
26 mm diameter stainless steel housing
Different options up to 5000 Bar
Analog 4-20mA / 0-10V etc. outputs
±%0,5 F.S accuracy
Compact design

Fully welded Thin-film steel diaphragm structure that does not require O-rings; High sensitivity; EMC and reverse polarition protection; Small and compact design

 Pressure Range Output Protection Accuracy Body Diameter Datasheet
Different options up to 5000 Bar 4-20 mA, 0-10 VDC, 0-20 mA, 1-6 VDC, 0-5 VDC, Ratiometric IP65 or IP67 ±%0,5 F.S 26mm

BCT 26 Pressure Transmitter || ATEK || Made in Türkiye

Piezoresistive working principle
Stainless steel housing (1.4305)
Optional 316L or titanium housing
Different models between 100 mBar and 600 Bar
Analog 4-20mA / 0-10V and so on different outputs
±0.3% F.S accuracy
IP65 or IP67 protection class
Compact construction

Stainless steel body; high sensitivity; EMC and reverse polarization protected; small and compact design

Measuring Range Output Protection Accuracy Body Diameter Datasheet
Different models from 0…100mbar to 0…600bar Different vacuum models from 0…-100mbar to 0…-1bar 4-20 mA, 0-10 VDC, 0-20 mA, 1-6 VDC, 0-5 VDC, Ratiometric etc. IP65 or IP67 ±%0,3 F.S  26mm

BLT 22 Pressure Transmitter || ATEK || Made in Türkiye

Piezoresistive working principle
Stainless steel housing
10Bar and 16Bar models
4-20mA analog output
±0.5% F.S accuracy
IP65 protection class
Compact construction

Stainless steel body; high sensitivity; EMC and reverse polarization protected; small and compact design

Measuring Range Output Protection Accuracy Body Diameter Datasheet
0…10bar and 0…16bar  4-20 mA IP65  ±%0,5 F.S 24mm

EPT 22 Pressure Transmitter || ATEK || Made in Türkiye

Piezoresistive measuring principle
Stainless steel housing (303)
10 Bar, 16 Bar, 0… -1 Bar, -1… 0 Bar Different options
4-20mA, 0-10 VDC or ratiometric output options
±1% F.S sensitivity
IP65 protection class
Compact construction

For air or non-corrosive gas applications

Measuring Range Output Protection Accuracy Datasheet
10 Bar, 16 Bar , 0…-1 Bar, -1…0 Bar 4-20 mA, 0-10 VDC, Ratiometric IP65  ±%1 F.S

BHT 26 Flush Pressure Transmitter for Sanitary Applications || ATEK ||

100mbar…100bar pressure range
Suitable for sanitary applications
Suitable for 1.5″ tri-clamp connection
±0.5%FS accuracy
4-20 mA, 0-10V etc. analog output options
IP65 protection

BT10-211 flush pressure transmitter is applicable to food, beverage, pharmaceutical and biological engineering. Full metal flush-mounting isolation diaphragm is directly welded with process connection to ensure the precision connection between process connection and measuring diaphragm. Therefore, no additional sealing gaskets are required, and it ensures there are no measurement dead zones.

 Pressure Range Output Protection Accuracy Datasheet
0…100 mBar to 0…100 Bar 4-20mA, 0-20mA, 0-10V, 1-6V, 0-5V, Ratiometric IP 65 ±0.5%FS

BT10 / BT20 / BT05 – 214 Flush Pressure Transmitter for High Temperature and Standard Applications || ATEK ||

1…0~0.1bar…600bar pressure range
Suitable for sanitary applications
±0.5%FS linearity
4-20 mA, 0-10V, 0-5V, 0.5-4.5V output
IP65 protection class
With cooling fan options, excellent performance for high temperature medium applications

Flush diaphragm; stainless steel body; high sensitivity; EMC and reverse polarity protection; for standard applications; high performance in high temperature applications up to 250°C with the option of cooling fan

 Pressure Range Output Operating Temperature Protection Linearity Datasheet
  -1…0~0.1bar…600bar 4-20mA, 0-10V, 0-5V, 0.5-4.5V -40~85°C (without cooling fan) 
-40~150°C (with 3 cooling fans)
-40°C~250°C (with 5 cooling fans) 
IP 65 ±0.5%FS

BT10-212 Flush Pressure Transmitter with Flange || ATEK ||

-1bar…0~0.002bar…100bar pressure range
Flange mounting
±0.3%FS accuracy
Double-wire mode, 4~20mA analog output, HART® protocol
IP65 protection class
Intelligent LCD gauge outfit with backlight

BT10-212 Flush Pressure Transmitter with Flange is a type of flush product in order to meet the flange mounting requirement of the customer. This series are widely applied for the viscous media with particles in the fields such as industrial process control, petroleum, chemical industry, metallurgy etc.

 Pressure Range Output Protection Accuracy Datasheet
-1bar…0~0.002bar…100bar 4-20mA, 4-20mA+HART IP 65 ±0.3%FS

BFT10-110 Differential Pressure Transmitter for Low Pressure || ATEK ||

0~0,0025bar…0,01bar…1bar pressure range
Suitable for low pressure
φ8 agnail connection, easy to install
±0.5%…±3%FS accuracy
4-20 mA analog output
IP65 protection class

BFT10-110 Differential Pressure Transmitter is ideal for use at low pressures. Pressure connection is in M10 thread and agnail structure. It is widely used in the field of automatic pressure detection and control for air supply in underground ventilation and other electrical and mining industries.

 Pressure Range Output Protection Accuracy Datasheet
0~0,0025bar…0,001bar…1bar 4-20mA IP 65 ±0.5%…±3%FS

BFT10-111 Differential Pressure Transmitter With Display for Low Pressure || ATEK ||

0~0,005bar…0,01bar…1bar pressure range
Suitable for low pressure
Diameter 10 barb structure pressure port
±0.5%…±1%FS accuracy
4-20 mA analog output
Built-in LCD display

BFT10-111 Differential Pressure Transmitter is ideal for use at low pressures. Pressure connection is in M10 thread and agnail structure. It is widely used in the field of automatic pressure detection and control for air supply in underground ventilation and other electrical and mining industries.


Datasheet
 Pressure Range Output Protection Accuracy Datasheet
0~0,005bar…0,001bar…1bar 4-20mA IP 65 ±0.5%…±1%FS

BFT 210 Differential Pressure Transmitter || ATEK ||

Piezoresistive silicone differential pressure sensor
Stainless steel housing (304)
Different models from 100 mBar to 25 Bar
4-20mA, 0-5 VDC or 1-5 VDC analog output options
±0.5% F.S accuracy
IP65 protection class
Compact construction

MEMS based piezoresistive silicon sensor; stainless steel body; long term stability and high precision; EMC and reverse polarity protection

Differential Pressure Measuring Range Output Protection Accuracy Datasheet
Different options from 100 mBar to 25 Bar 4-20 mA, 0-5 VDC, 1-5VDC IP65  ±%0,5 F.S